Unimotor - Motor Specification
Machinery Directive 89/392/EEC amended to 98/37/EC Low Voltage Directive 73/23/EEC
| EN 60034 |
General requirements for rotating electrical machinery |
| EN 60034-1 |
Duty: S1 Continuous
Storage: -15º to +40º Operating: Min ambient 0ºC; max ambient 40ºC
Less than 1000M altitude
Relative humidity: 90% non condensing |
| EN 60034-5 |
Degree of Ingress protection: IP65 (with mating connector & cable fitted) |
| EN 60034-6 |
Method of cooling: free circulation, free convection |
| EN 60034-7 |
Flange mounted: horizontally or vertically |
| EN 60034-8 |
Terminal markings: U V W, |
| EN 60034-11 |
Thermal protection: PTC thermistor, 145ºC on 075-190 motors
Thermal protection: PTC thermistor, 150ºC on 055 motors |
| EN 60034-18 |
Insulation system: Class F 600V, UL number E214439 on 075-190 motors
Insulation system: Class F 600V, on 055 motors |
| EN 60034-25 |
The design and performance of motors specifically designed for converter supply |
| EN 60072 |
Dimensions and output for rotating electrical machines |
| EN 60072-1 |
Type N (Customer variants) |
| ISO1940-1 |
Balancing: to G6.3, (ISO8821 half key convention) |
Standard equipment is not deemed suitable for use in an explosive atmosphere. (ATEX motors are available, please contact your Drive Centre or Distributor for details). This product has been designed to be operated with Control Techniques Servo drives and must not be put into service unless the machinery into which it is to be incorporated has been declared in conformity with the provisions of the machinery directive.
|