Unimotor Unimotor FM Logo - Motor Specification

 

Machinery Directive 89/392/EEC amended to 98/37/EC Low Voltage Directive 73/23/EEC

 

EN 60034 General requirements for rotating electrical machinery
EN 60034-1 Duty: S1 Continuous
Storage: -15º to +40º Operating: Min ambient 0ºC; max ambient 40ºC
Less than 1000M altitude
Relative humidity: 90% non condensing
EN 60034-5 Degree of Ingress protection: IP65 (with mating connector & cable fitted)
EN 60034-6 Method of cooling: free circulation, free convection
EN 60034-7 Flange mounted: horizontally or vertically
EN 60034-8 Terminal markings: U V W,
EN 60034-11

Thermal protection: PTC thermistor, 145ºC on 075-190 motors

Thermal protection: PTC thermistor, 150ºC on 055 motors

EN 60034-18 Insulation system: Class F 600V, UL number E214439 on 075-190 motors
Insulation system: Class F 600V, on 055 motors
EN 60034-25 The design and performance of motors specifically designed for converter supply
EN 60072 Dimensions and output for rotating electrical machines
EN 60072-1 Type N (Customer variants)
ISO1940-1 Balancing: to G6.3, (ISO8821 half key convention)

 

Standard equipment is not deemed suitable for use in an explosive atmosphere. (ATEX motors are available, please contact your Drive Centre or Distributor for details). This product has been designed to be operated with Control Techniques Servo drives and must not be put into service unless the machinery into which it is to be incorporated has been declared in conformity with the provisions of the machinery directive.