Motor Frame
Supply Volts
Input Power
Static Torque
Release Time
Moment of Inertia
Backlash
Size
VDC
Watts
Nm
ms nom.
kgcm2*
Degrees**
55
24
6.3
1.8
22
0.03
0.75
75
24
6.3
2
22
0.07
1.03
95
24
16
11
60
0.39
0.94
115
24
16
11
60
0.44
0.56
142
24
19.5
18
75
0.54
0.56
190(A-D)
24
25
38
95
3.07
0.77
190(E-H)
24
25
60
120
4.95
0.77

 

*Note 1 kgcm2 = 1x10-4kgm2 **Backlash figure will increase with time