Unimotor - Brake Specification
- The brakes are intended for parking duty and are not for dynamic or safety use.
- The brake will engage when power is removed.
- Refer to your Drive Centre or Distributor if your application requires dynamic braking in emergency conditions.
- To provide protection to the brake control circuit it is recommended that a diode is connected across the output
terminals of the solid state or relay contacts devices.
- Larger torque brakes are available as an option. Please contact your Drive Centre or Distributor for details.
- Figures are shown at 20°C brake temperature. Apply the de rate factor of 0.7 if motor temperature is above 100°C.
55 |
24 |
6.3 |
1.8 |
22 |
0.03 |
0.75 |
75 |
24 |
6.3 |
2 |
22 |
0.07 |
1.03 |
95 |
24 |
16 |
11 |
60 |
0.39 |
0.94 |
115 |
24 |
16 |
11 |
60 |
0.44 |
0.56 |
142 |
24 |
19.5 |
18 |
75 |
0.54 |
0.56 |
190(A-D) |
24 |
25 |
38 |
95 |
3.07 |
0.77 |
190(E-H) |
24 |
25 |
60 |
120 |
4.95 |
0.77 |
*Note 1 kgcm2 = 1x10-4kgm2 **Backlash figure will increase with time
|